蒙地卡羅法MCNP程式對多層屏蔽
之光子曝露增建因數研究
謝楊威1 林威廷2
1慈濟技術學院放射醫學科學研究所理學碩士
2慈濟技術學院放射醫學科學研究所助理教授
摘要
屏蔽設施為多層屏蔽時,由於增建因數的變化相當複雜,若點核仁法採用單層屏蔽增建因數,容易得到低估或過度高估的結果。本研究以簡單及容易使用為考量,選取平面單向射源平板雙層屏蔽的Kalos、Modified Kalos經驗公式,以及點射源球形雙層及多層屏蔽的Lin & Jiang經驗公式,分別和使用蒙地卡羅法MCNP5程式計算點均向射源(0.1、0.3、0.6、1、3、6、10 MeV),在三種不同材質(水、鐵及鉛)的球形多層屏蔽曝露增建因數的計算值進行比較,以驗證各經驗公式的適用性程度。在雙層屏蔽,Lin & Jiang經驗公式在入射光子能量為0.1至
關鍵字:經驗公式、蒙地卡羅法、MCNP、曝露增建因數
The Study of Photon Exposure Buildup Factors for Multi - Layer Shields Using MCNP Monte Carlo Code
Yang-Wei Hsieh 1 Uei-Tyng Lin 2
1 Master of Science, Institute of Radiological Science,
2 Assistant Professor, Institute of Radiological Science,
Abstract
Concerning multi-layered shields, the variation in buildup factor is complicated. If buildup factors for single-layered spherical shields are adopted in point-kernel codes, underestimate or overestimate results are likely to be obtained. Simple and easy to use are the considerations of this study. Kalos and Modified Kalos empirical formulas of double-layered slabs at plane monodirectional source, and Lin & Jiang empirical formula of double-and multi-layered spherical shields consisting of three kinds of different materials (water, iron, and lead) at point isotropic source (0.1, 0.3, 0.6, 1, 3, 6, and 10 MeV) are selected to be compared with the theoretical calculated value of MCNP5, in order to verify the applicability of each empirical formula. In double-layered shield, the overall applicability and improvement of Lin & Jiang empirical formula are more significant when the energy of incident photon is 0.1 to 10 MeV. As for Kalos and Modified Kalos empirical formulas, it is likely to cause overestimation result when the energy of incident photon is 0.1 MeV and low atomic number material is linked with high atomic number material (water/lead, iron/lead) behind. When double-layered spherical shields at point isotropic source expands to multi-layered and the energy of incident photon is 0.3 to 10 MeV, the exposure buildup factors calculated values of Lin & Jiang empirical formula are more similar to the calculated results of MCNP5. If the energy of incident photon is 0.1 MeV, significant improvement can be found when comparing the results of Lin & Jiang empirical formula and those directly adopt ANSI/ANS-
Keywords:empirical formula, Monte Carlo method, MCNP, exposure buildup factor.